₨ 1,285,000 Original price was: ₨ 1,285,000.₨ 1,092,250Current price is: ₨ 1,092,250.
A banquet hall full of guests in June. A factory floor where machines add heat all day. A showroom that has to stay comfortable from opening to closing. These spaces need serious cooling capacity, and in winter they need heating too.
The TCL TCC-96HRA is built for this kind of work. It is a high-capacity inverter floor-standing commercial air conditioner rated at approximately 96,000 BTU, which puts it in the 8 Ton and 10 HP class. It offers both cooling and heating, so one unit can handle Pakistan’s hot summers and cold winter mornings.
The unit combines a high-efficiency centrifugal fan, wide-angle 180° air distribution, and long-distance air supply. Together, these features push conditioned air across large, high-occupancy areas. Its durable metal cabinet, dust-resistant design, and multiple protection functions make it a practical choice for demanding commercial and industrial sites.
At a glance:
The TCL TCC-96HRA is an inverter floor-standing commercial air conditioner with a capacity of approximately 96,000 BTU/h, equal to the 8 Ton or 10 HP class. It provides both heating and cooling.
Matching TCC-96FHRA documentation identifies the system as an inverter floor-standing unit that uses R410A refrigerant. Key features include a high-efficiency centrifugal fan, wide-angle 180° airflow, long-distance air supply, auto restart, rapid start, wide-voltage operation, and protection against voltage issues, overcurrent, overheating, and phase loss.
It suits large halls, restaurants, banquet halls, factories, workshops, warehouses, showrooms, waiting areas, event venues, and large offices.
Big, open rooms are hard to condition with smaller split units. Air often stays close to the unit, while the far side of the hall stays warm. Adding several small units also means more installation points, more wiring, and more maintenance visits.
An 8 Ton Inverter AC solves this with one high-capacity system. It delivers strong airflow from a single floor-standing cabinet, so you can cover a large area without crowding walls or ceilings with equipment.
The floor-standing format adds flexibility. It needs no false ceiling or ceiling cutouts, which helps in warehouses, factories, rented premises, and halls with high or exposed ceilings. You can place the unit where airflow matters most, such as near seating zones, entrances, or work areas.
No. Floor area is only one part of the cooling and heating load. Ceiling height, glass walls, sun exposure, kitchen heat, machinery, lighting, and the number of people inside all affect how much capacity you need.
A busy restaurant or factory floor needs more capacity than a quiet office of the same size. Our engineers can assess your site and confirm whether one unit is enough or whether multiple units will give better coverage.
Each feature connects to a practical benefit for your business.
The unit provides both cooling and heating. In summer, it delivers strong cooling for crowded halls and workspaces. In winter, it supplies heating, so you don’t need separate heaters for the same space.
Rapid start helps the unit reach working output quickly after you switch it on. Auto restart brings the system back to operation after a power interruption. For businesses that deal with load shedding or supply cuts, this saves staff from resetting the unit every time power returns.
Voltage fluctuations are common at many commercial sites. Wide-voltage operation helps the unit keep working across a broader voltage range, which supports more dependable performance where supply quality varies.
Large commercial and industrial buildings often run on three-phase supply. The three-phase power option makes the unit easier to integrate into these electrical systems. Our team will confirm the correct power arrangement for your site before installation.
The commercial-grade metal cabinet is built for demanding environments. Its dust-resistant design suits factories, workshops, and warehouses where dust levels are higher than in a typical office.
As a floor-standing unit, it is simpler to install than ceiling-mounted systems. Technicians can also reach it more easily for routine cleaning and service.
Strong capacity only helps if the air actually reaches people across the room. This unit focuses on wide, even, long-range air delivery.
The centrifugal fan moves a large volume of air with strong pressure. This helps push conditioned air further into big spaces rather than letting it settle near the unit.
The 180° air distribution spreads airflow across a broad arc. Guests at side tables, customers along showroom walls, and workers at the edges of a factory floor all feel the effect, not just those standing in front of the unit.
The 3D fan design supports smooth, multi-directional airflow. Combined with long-distance air supply, it helps carry air deep into long halls and open-plan areas. TCL documentation describes the commercial floor-standing design as providing strong cooling and heating with wide, uniform air supply and long-distance airflow.
Mini-summary: The fan, airflow angle, and air throw work together so large rooms feel evenly comfortable, not just cool near the unit.
Traditional fixed-speed systems switch the compressor fully on and fully off. Each cycle causes temperature swings and draws extra power at startup.
The TCL aircon inverter system works differently. The inverter compressor adjusts its operating frequency to match the actual cooling or heating load. When the room needs more capacity, it speeds up. When the target temperature is reached, it slows down instead of stopping completely.
Matching TCC-96FHRA information describes full DC inverter technology, energy-saving operation, and more precise temperature regulation. For restaurants, halls, and factories that run air conditioning for many hours a day, this approach supports better control over running costs.
|
Factor |
Inverter Operation |
Fixed-Speed Operation |
|---|---|---|
|
Compressor behavior |
Adjusts speed to match the load |
Switches fully on and off |
|
Temperature stability |
More stable and precise |
Larger temperature swings |
|
Power use |
Reduces unnecessary consumption |
Higher draw from repeated starts |
|
Long operating hours |
Smoother, steadier performance |
More stop-start cycling |
Commercial sites face electrical challenges that can damage equipment. Available documentation identifies several protection functions built into this system:
These safeguards, together with auto restart and wide-voltage operation, help the unit cope with real-world supply conditions in Pakistan. The metal cabinet and dust-resistant build add further durability for industrial and high-traffic settings.
|
Specification |
Details |
|---|---|
|
Brand |
TCL |
|
Model |
TCC-96HRA |
|
Product Type |
Floor Standing Commercial AC |
|
Capacity |
Approximately 96,000 BTU/h |
|
Capacity Class |
8 Ton / 10 HP class |
|
Operation |
Heat & Cool |
|
Technology |
Inverter |
|
Refrigerant |
R410A (per matching TCC-96FHRA documentation) |
|
Fan |
High-efficiency centrifugal fan, 3D fan design |
|
Air Distribution |
Wide-angle 180°, long-distance air supply |
|
Convenience Functions |
Auto restart, rapid start |
|
Electrical |
Wide-voltage operation, three-phase power option |
|
Protection |
Voltage, overcurrent, overheating, and phase-loss protection |
|
Construction |
Durable metal cabinet, dust-resistant design |
|
Installation |
Floor Standing |
|
Application |
Commercial & Industrial |
Note: Some details are drawn from matching TCC-96FHRA documentation. Please confirm the exact model specifications, power supply, dimensions, and warranty terms with our sales team before ordering.
The unit is designed for high-occupancy and large-volume indoor areas, including:
|
Your Situation |
Good Fit? |
|---|---|
|
Banquet hall, marquee, or event venue |
Yes |
|
Restaurant with large dining areas |
Yes |
|
Factory, workshop, or warehouse |
Yes |
|
Car showroom or retail outlet |
Yes |
|
Large open-plan office or waiting area |
Yes |
|
Site needing both heating and cooling |
Yes |
|
Building with three-phase supply |
Yes |
|
Small office or single bedroom |
A smaller split unit may suit you better |
Workman Services has delivered HVAC&R and firefighting solutions across Pakistan since 2006. Our team of designers, qualified sales engineers, and certified technicians handles system design, supply, installation, testing, commissioning, and maintenance.
We have completed HVAC, VRF, and firefighting works for well-known commercial clients, including projects at Nishat Galleria Mall, Dolmen Mall outlets, Giga Mall, and MM Alam Road. Our experience covers apartments and villas, offices and IT companies, automotive showrooms, manufacturing units, resorts, and hospitals.
When you buy TCL aircon units from us, you get:
Our Lahore office is at M1, M2 Bara Tower, 36 Queens Road, Abid Market, Qartaba Chowk, Lahore.
It has a capacity of approximately 96,000 BTU/h, which places it in the 8 Ton and 10 HP class. It suits large commercial and industrial spaces.
Yes. The TCC-96HRA offers both heating and cooling, so one unit can handle summer and winter comfort in the same space.
The inverter compressor adjusts its speed to match the load instead of switching fully on and off. This helps reduce unnecessary power use and keeps indoor temperatures more stable.
Matching TCC-96FHRA documentation identifies R410A refrigerant. Confirm the exact configuration with our team before ordering.
Available documentation lists voltage, overcurrent, overheating, and phase-loss protection. Auto restart and wide-voltage operation add further reliability.
The unit offers a three-phase power option. Our engineers will confirm the correct electrical setup for your building.
The high-efficiency centrifugal fan, 3D fan design, and long-distance air supply carry air deep into large halls, while the 180° distribution spreads it across a wide area.
It suits halls, restaurants, banquet halls, factories, workshops, warehouses, showrooms, waiting areas, event venues, and large offices.
Contact Workman Services by phone or WhatsApp at +92 306 4410583, or email info@workmanservices.com.pk. Our team will confirm pricing, availability, specifications, and installation details.
Powerful cooling in summer, dependable heating in winter, and wide, long-range airflow in one commercial-grade cabinet. The TCC-96HRA brings approximately 96,000 BTU capacity, inverter efficiency, and multiple protection functions to Pakistan’s largest halls, restaurants, and industrial sites.