workmanservices
workmanservices

TCL 8 Ton Inverter Floor Standing Commercial AC Heat and Cool TCC-96HRA

Sale!

TCL 8 Ton Inverter Floor Standing Commercial AC Heat and Cool TCC-96HRA

  • TCL 8 Ton Inverter Floor Standing
  • Model: TCC-96HRA
  • Call/WhatsApp 0306-4410583
  • 96,000 BTU High-Capacity AC
  • 8 Ton Inverter Floor Standing
  • Heat & Cool Operation
  • Strong Airflow for Large Spaces
  • R410A Refrigerant
  • Wide 180° Air Distribution
  • 3D Fan Design
  • Energy-Saving Inverter Technology
  • Auto Restart & Rapid Start
  • Commercial-Grade Construction

Price

Original price was: ₨ 1,285,000.Current price is: ₨ 1,092,250.

TCL Floor Standing AC TCC-96HRA: 8 Ton Inverter Heat and Cool Unit for Large Commercial Spaces

A banquet hall full of guests in June. A factory floor where machines add heat all day. A showroom that has to stay comfortable from opening to closing. These spaces need serious cooling capacity, and in winter they need heating too.

The TCL TCC-96HRA is built for this kind of work. It is a high-capacity inverter floor-standing commercial air conditioner rated at approximately 96,000 BTU, which puts it in the 8 Ton and 10 HP class. It offers both cooling and heating, so one unit can handle Pakistan’s hot summers and cold winter mornings.

The unit combines a high-efficiency centrifugal fan, wide-angle 180° air distribution, and long-distance air supply. Together, these features push conditioned air across large, high-occupancy areas. Its durable metal cabinet, dust-resistant design, and multiple protection functions make it a practical choice for demanding commercial and industrial sites.

At a glance:

  • Approximately 96,000 BTU/h capacity (8 Ton / 10 HP class)
  • Inverter technology for steadier temperatures and energy-saving operation
  • Heat and cool operation in one unit
  • Wide-angle 180° air distribution with long-distance air supply
  • High-efficiency centrifugal fan with 3D fan design
  • R410A refrigerant
  • Voltage, overcurrent, overheating, and phase-loss protection
  • Three-phase power option and wide-voltage operation

Quick Answer: What Is the TCL Floor Standing AC TCC-96HRA?

The TCL TCC-96HRA is an inverter floor-standing commercial air conditioner with a capacity of approximately 96,000 BTU/h, equal to the 8 Ton or 10 HP class. It provides both heating and cooling.

Matching TCC-96FHRA documentation identifies the system as an inverter floor-standing unit that uses R410A refrigerant. Key features include a high-efficiency centrifugal fan, wide-angle 180° airflow, long-distance air supply, auto restart, rapid start, wide-voltage operation, and protection against voltage issues, overcurrent, overheating, and phase loss.

It suits large halls, restaurants, banquet halls, factories, workshops, warehouses, showrooms, waiting areas, event venues, and large offices.

Why Choose an 8 Ton Inverter AC for Large Spaces?

Big, open rooms are hard to condition with smaller split units. Air often stays close to the unit, while the far side of the hall stays warm. Adding several small units also means more installation points, more wiring, and more maintenance visits.

An 8 Ton Inverter AC solves this with one high-capacity system. It delivers strong airflow from a single floor-standing cabinet, so you can cover a large area without crowding walls or ceilings with equipment.

The floor-standing format adds flexibility. It needs no false ceiling or ceiling cutouts, which helps in warehouses, factories, rented premises, and halls with high or exposed ceilings. You can place the unit where airflow matters most, such as near seating zones, entrances, or work areas.

Does Capacity Alone Decide the Right Unit?

No. Floor area is only one part of the cooling and heating load. Ceiling height, glass walls, sun exposure, kitchen heat, machinery, lighting, and the number of people inside all affect how much capacity you need.

A busy restaurant or factory floor needs more capacity than a quiet office of the same size. Our engineers can assess your site and confirm whether one unit is enough or whether multiple units will give better coverage.

Key Features of the TCL Aircon TCC-96HRA

Each feature connects to a practical benefit for your business.

Heat and Cool Operation

The unit provides both cooling and heating. In summer, it delivers strong cooling for crowded halls and workspaces. In winter, it supplies heating, so you don’t need separate heaters for the same space.

Rapid Start and Auto Restart

Rapid start helps the unit reach working output quickly after you switch it on. Auto restart brings the system back to operation after a power interruption. For businesses that deal with load shedding or supply cuts, this saves staff from resetting the unit every time power returns.

Wide-Voltage Operation

Voltage fluctuations are common at many commercial sites. Wide-voltage operation helps the unit keep working across a broader voltage range, which supports more dependable performance where supply quality varies.

Three-Phase Power Option

Large commercial and industrial buildings often run on three-phase supply. The three-phase power option makes the unit easier to integrate into these electrical systems. Our team will confirm the correct power arrangement for your site before installation.

Durable Metal Cabinet and Dust-Resistant Design

The commercial-grade metal cabinet is built for demanding environments. Its dust-resistant design suits factories, workshops, and warehouses where dust levels are higher than in a typical office.

Easy Installation and Maintenance

As a floor-standing unit, it is simpler to install than ceiling-mounted systems. Technicians can also reach it more easily for routine cleaning and service.

Airflow and Comfort: Reaching Every Corner

Strong capacity only helps if the air actually reaches people across the room. This unit focuses on wide, even, long-range air delivery.

High-Efficiency Centrifugal Fan

The centrifugal fan moves a large volume of air with strong pressure. This helps push conditioned air further into big spaces rather than letting it settle near the unit.

Wide-Angle 180° Air Distribution

The 180° air distribution spreads airflow across a broad arc. Guests at side tables, customers along showroom walls, and workers at the edges of a factory floor all feel the effect, not just those standing in front of the unit.

3D Fan Design and Long-Distance Air Supply

The 3D fan design supports smooth, multi-directional airflow. Combined with long-distance air supply, it helps carry air deep into long halls and open-plan areas. TCL documentation describes the commercial floor-standing design as providing strong cooling and heating with wide, uniform air supply and long-distance airflow.

Mini-summary: The fan, airflow angle, and air throw work together so large rooms feel evenly comfortable, not just cool near the unit.

Energy Efficiency: How the TCL Aircon Inverter System Works

Traditional fixed-speed systems switch the compressor fully on and fully off. Each cycle causes temperature swings and draws extra power at startup.

The TCL aircon inverter system works differently. The inverter compressor adjusts its operating frequency to match the actual cooling or heating load. When the room needs more capacity, it speeds up. When the target temperature is reached, it slows down instead of stopping completely.

What This Means for Your Business

  • Steadier indoor temperatures: Fewer swings between too hot and too cold.
  • Less unnecessary power use: The compressor runs only as hard as the load requires.
  • Smoother operation: Reduced stop-start cycling during long business hours.

Matching TCC-96FHRA information describes full DC inverter technology, energy-saving operation, and more precise temperature regulation. For restaurants, halls, and factories that run air conditioning for many hours a day, this approach supports better control over running costs.

Inverter vs. Fixed-Speed Operation

Factor

Inverter Operation

Fixed-Speed Operation

Compressor behavior

Adjusts speed to match the load

Switches fully on and off

Temperature stability

More stable and precise

Larger temperature swings

Power use

Reduces unnecessary consumption

Higher draw from repeated starts

Long operating hours

Smoother, steadier performance

More stop-start cycling

Protection and Reliability for Commercial Use

Commercial sites face electrical challenges that can damage equipment. Available documentation identifies several protection functions built into this system:

  • Voltage protection: Helps guard the unit during abnormal voltage conditions.
  • Overcurrent protection: Helps prevent damage from excess electrical current.
  • Overheating protection: Helps protect components when operating temperatures rise too high.
  • Phase-loss protection: Helps protect three-phase systems if one phase drops out.

These safeguards, together with auto restart and wide-voltage operation, help the unit cope with real-world supply conditions in Pakistan. The metal cabinet and dust-resistant build add further durability for industrial and high-traffic settings.

TCL Floor Standing AC Technical Specifications

Specification

Details

Brand

TCL

Model

TCC-96HRA

Product Type

Floor Standing Commercial AC

Capacity

Approximately 96,000 BTU/h

Capacity Class

8 Ton / 10 HP class

Operation

Heat & Cool

Technology

Inverter

Refrigerant

R410A (per matching TCC-96FHRA documentation)

Fan

High-efficiency centrifugal fan, 3D fan design

Air Distribution

Wide-angle 180°, long-distance air supply

Convenience Functions

Auto restart, rapid start

Electrical

Wide-voltage operation, three-phase power option

Protection

Voltage, overcurrent, overheating, and phase-loss protection

Construction

Durable metal cabinet, dust-resistant design

Installation

Floor Standing

Application

Commercial & Industrial

Note: Some details are drawn from matching TCC-96FHRA documentation. Please confirm the exact model specifications, power supply, dimensions, and warranty terms with our sales team before ordering.

Suitable Applications for This 8 Ton Commercial AC

The unit is designed for high-occupancy and large-volume indoor areas, including:

  • Large commercial halls
  • Restaurants and banquet halls
  • Factories and workshops
  • Warehouses
  • Showrooms
  • Waiting areas
  • Event venues
  • Large offices
  • Retail and commercial spaces
  • Other large-volume indoor areas

Is This 8 Ton Commercial AC Right for Your Space?

Your Situation

Good Fit?

Banquet hall, marquee, or event venue

Yes

Restaurant with large dining areas

Yes

Factory, workshop, or warehouse

Yes

Car showroom or retail outlet

Yes

Large open-plan office or waiting area

Yes

Site needing both heating and cooling

Yes

Building with three-phase supply

Yes

Small office or single bedroom

A smaller split unit may suit you better

Installation and Buying Tips

  1. Get a load assessment. Room volume, occupancy, and heat sources decide the right capacity.
  2. Confirm your power supply. Check three-phase availability and electrical requirements for your site.
  3. Choose the right placement. Position the unit where its 180° airflow can spread freely without obstructions.
  4. Plan outdoor unit location. Allow proper space and ventilation for the outdoor section.
  5. Confirm model details. Verify specifications and warranty terms before you place your order.
  6. Schedule regular maintenance. Routine filter cleaning and servicing help keep performance steady.

Why Buy From Workman Services

Workman Services has delivered HVAC&R and firefighting solutions across Pakistan since 2006. Our team of designers, qualified sales engineers, and certified technicians handles system design, supply, installation, testing, commissioning, and maintenance.

We have completed HVAC, VRF, and firefighting works for well-known commercial clients, including projects at Nishat Galleria Mall, Dolmen Mall outlets, Giga Mall, and MM Alam Road. Our experience covers apartments and villas, offices and IT companies, automotive showrooms, manufacturing units, resorts, and hospitals.

When you buy TCL aircon units from us, you get:

  • Load assessment and capacity planning by experienced engineers
  • Professional installation, testing, and commissioning
  • After-sales maintenance and customer support
  • Branch support in Lahore, Rawalpindi, and Faisalabad

Our Lahore office is at M1, M2 Bara Tower, 36 Queens Road, Abid Market, Qartaba Chowk, Lahore.

Frequently Asked Questions

What is the capacity of the TCL Floor Standing AC TCC-96HRA?

It has a capacity of approximately 96,000 BTU/h, which places it in the 8 Ton and 10 HP class. It suits large commercial and industrial spaces.

Does the TCL aircon inverter heat as well as cool?

Yes. The TCC-96HRA offers both heating and cooling, so one unit can handle summer and winter comfort in the same space.

Is an 8 Ton Inverter AC more efficient than a fixed-speed unit?

The inverter compressor adjusts its speed to match the load instead of switching fully on and off. This helps reduce unnecessary power use and keeps indoor temperatures more stable.

What refrigerant does the TCC-96HRA use?

Matching TCC-96FHRA documentation identifies R410A refrigerant. Confirm the exact configuration with our team before ordering.

What protection features does it include?

Available documentation lists voltage, overcurrent, overheating, and phase-loss protection. Auto restart and wide-voltage operation add further reliability.

Does it need three-phase power?

The unit offers a three-phase power option. Our engineers will confirm the correct electrical setup for your building.

How far does the airflow reach?

The high-efficiency centrifugal fan, 3D fan design, and long-distance air supply carry air deep into large halls, while the 180° distribution spreads it across a wide area.

Which spaces suit this unit?

It suits halls, restaurants, banquet halls, factories, workshops, warehouses, showrooms, waiting areas, event venues, and large offices.

Where can I buy TCL aircon in Pakistan?

Contact Workman Services by phone or WhatsApp at +92 306 4410583, or email info@workmanservices.com.pk. Our team will confirm pricing, availability, specifications, and installation details.

Order Your TCL Floor Standing AC From Workman Services

Powerful cooling in summer, dependable heating in winter, and wide, long-range airflow in one commercial-grade cabinet. The TCC-96HRA brings approximately 96,000 BTU capacity, inverter efficiency, and multiple protection functions to Pakistan’s largest halls, restaurants, and industrial sites.

Call or WhatsApp Workman Services at +92 306 4410583 to confirm the right capacity for your space, get a quote, and plan a professional installation backed by nearly two decades of HVAC experience.

Related Products