A clothing store in Faisalabad fills with shoppers on a hot June evening. The wall split near the counter keeps the cashier cool, but customers at the back still feel the heat. That split also takes up wall space the owner would rather use for display racks. In winter, the same store feels cold and damp, and staff bring in a heater.
A ceiling cassette solves both problems. The Hitachi Cassette AC model RCI-3.0UNZ1NH / RAS-3.0UNZGNH1 sits neatly in the ceiling and spreads air across the room from above. It delivers 23,300 BTU/h of cooling and 25,640 BTU/h of heating. It runs on R410A refrigerant and includes high ambient technology for hot climates.
Workman Services has designed, supplied, installed, and maintained HVAC systems across Pakistan since 2006. This guide explains what this unit offers, how it works, where it fits best, and what to check before you buy.
The Hitachi RCI-3.0UNZ1NH / RAS-3.0UNZGNH1 is a 2-ton, non-inverter, heat and cool ceiling cassette air conditioner. The RCI-3.0UNZ1NH is the indoor cassette unit. The RAS-3.0UNZGNH1 is the matching outdoor unit.
Here are the core facts:
It suits offices, shops, showrooms, restaurants, hotels, clinics, large residential rooms, and conference rooms.
Specifications are easier to judge when you know what each one does in daily use. This table links every feature to a real benefit.
|
Feature |
What It Means in Practice |
|---|---|
|
2-ton heat and cool capacity |
One unit for summer cooling and winter heating |
|
Non-inverter operation |
Simple, proven fixed-speed compressor |
|
Ceiling cassette design |
Walls and floor stay free |
|
23,300 BTU/h cooling |
Strong cooling for large rooms and commercial spaces |
|
25,640 BTU/h heating |
Higher output in winter mode |
|
R410A refrigerant |
A widely used refrigerant in modern systems |
|
EER 2.81 / COP 3.41 W/W |
Clear efficiency figures you can compare |
|
High ambient technology |
Designed for high outdoor temperatures |
|
Washable filter |
Easy cleaning between service visits |
|
Auto restart function |
Resumes settings after a power cut |
|
PCB surge protection |
Helps guard the circuit board from voltage spikes |
|
Anti-corrosion outdoor heat exchanger |
Better resistance to humidity and pollution |
|
Fireproof electrical enclosure |
Added safety around electrical parts |
|
Infrared remote controller |
Easy control without reaching the ceiling |
|
220–240V, 1 phase, 50Hz |
Works on standard single-phase supply |
Capacity decides whether a room actually feels comfortable. This unit covers both seasons with solid output.
With 23,300 BTU/h of cooling, the unit handles spaces that need more than a typical bedroom split. Busy shops, open offices, and meeting rooms full of people all add heat. This capacity helps bring those rooms down to a comfortable temperature during long summer afternoons.
Heating output is higher than cooling output at 25,640 BTU/h. That makes the unit a practical choice for winter in Lahore, Rawalpindi, Islamabad, and other cities with cold, foggy mornings. You can replace a separate gas or electric heater in the same room with one system.
These two figures show how well the unit turns electricity into comfort:
A COP above 3 means heating mode produces more than three times the heat energy it draws from the grid.
Mini-summary: Strong summer cooling, higher winter heating, and published efficiency figures for easy comparison.
A non-inverter system uses a fixed-speed compressor. It runs at full power until the room reaches the set temperature, then switches off. When the room warms up or cools down again, the compressor switches back on.
This design brings some clear advantages:
|
Factor |
Non-Inverter (This Model) |
Inverter Systems |
|---|---|---|
|
Compressor speed |
Fixed, switches on and off |
Varies with demand |
|
Temperature control |
Cycles around the set point |
Holds the set point more closely |
|
Electronics |
Simpler |
More complex |
|
Good fit |
Scheduled, steady use |
Long or variable running hours |
This type of system suits spaces with predictable use. Think of shops open during business hours, conference rooms booked for set meetings, or clinics with fixed timings. If your space runs around the clock with changing loads, ask our team about inverter alternatives before deciding.
A ceiling cassette sits flush inside a false ceiling. Only a neat grille panel shows from below.
Walls stay free for shelves, signage, artwork, and windows. The floor stays completely clear. For showrooms, boutiques, hotel rooms, and clinics, this keeps the interior looking tidy and professional.
Because the unit sits in the ceiling, air spreads across the room from above instead of blowing from one wall. This helps avoid the usual problem where people near the unit feel cold while far corners stay warm. It works especially well in square or open-plan rooms.
Good results depend on good planning. A well-placed unit cools and heats evenly. A poorly placed one leaves hot and cold patches.
The best position is usually near the center of the room, where airflow can reach every corner. Avoid spots directly above heat sources such as kitchen equipment or display lighting. In long rooms, think about where people sit or stand most often.
Workman Services surveys your site before installation, so these points are settled early.
Many air conditioners lose cooling power when outdoor temperatures rise very high. Unfortunately, that’s exactly when you need them most. Hitachi’s high ambient technology is designed to keep the system performing in hot outdoor conditions.
This makes the unit a strong fit for Pakistan, where summers in Lahore, Faisalabad, and Multan push temperatures to extreme levels.
Commercial air conditioners face long running hours, dust, humidity, and unstable power. This model includes several protective features.
The outdoor heat exchanger has anti-corrosion protection. This helps it cope with monsoon humidity and pollution in busy urban areas.
Voltage spikes are common in many markets and neighborhoods. PCB surge protection helps guard the circuit board against sudden power surges.
A fireproof enclosure surrounds the electrical components. This adds peace of mind in offices, clinics, hotels, and retail spaces.
When power returns after a cut, the unit restarts with its previous settings. Nobody needs to reset it by hand, which helps when staff aren’t nearby.
The filter can be removed, washed, and refitted, which helps maintain airflow between service visits. The infrared remote lets you change modes and temperature without touching the ceiling unit.
The Hitachi 2 Ton AC fits spaces that need solid capacity, year-round comfort, and a clean ceiling finish.
|
Space |
Why It Fits |
|---|---|
|
Offices and workspaces |
Even overhead airflow across desks |
|
Shops and retail stores |
Walls stay free for displays |
|
Showrooms |
Discreet, professional ceiling finish |
|
Restaurants and cafés |
Heat and cool comfort for diners |
|
Hotels and guest rooms |
Out-of-the-way placement |
|
Clinics and commercial areas |
Fireproof enclosure and auto restart |
|
Large residential rooms |
Strong capacity for lounges and drawing rooms |
|
Conference and meeting rooms |
Group comfort without wall clutter |
For larger halls or multi-zone buildings, multiple units or a VRF, chiller, or AHU system may suit you better. Workman Services designs and installs all of these.
|
Specification |
Details |
|---|---|
|
Brand |
Hitachi |
|
Model |
RCI-3.0UNZ1NH / RAS-3.0UNZGNH1 |
|
Indoor Unit |
RCI-3.0UNZ1NH |
|
Outdoor Unit |
RAS-3.0UNZGNH1 |
|
Type |
Ceiling Cassette |
|
Technology |
Non-Inverter |
|
Operation |
Heat & Cool |
|
Capacity |
2 Ton |
|
Cooling Capacity |
23,300 BTU/h |
|
Heating Capacity |
25,640 BTU/h |
|
Refrigerant |
R410A |
|
Cooling EER |
2.81 W/W |
|
Heating COP |
3.41 W/W |
|
Climate Feature |
High ambient technology |
|
Filter |
Washable |
|
Restart |
Auto restart function |
|
Electrical Protection |
PCB surge protection |
|
Outdoor Heat Exchanger |
Anti-corrosion |
|
Electrical Enclosure |
Fireproof |
|
Controller |
Infrared remote |
|
Power Supply |
220–240V, 1 Phase, 50Hz |
Note: Please confirm final dimensions, pricing, availability, and warranty terms with our team before purchase.
Since 2006, Workman Services has delivered HVAC&R and fire fighting solutions for residential, commercial, industrial, hospital, office, and retail projects. Our designers, qualified sales engineers, and certified technicians handle design, supply, installation, testing, commissioning, and maintenance.
We work with top brands, including Hitachi. Our project experience includes HVAC and fire fighting work at Nishat Galleria Mall, outlets in Dolmen Mall, Haseens at Giga Mall, and Zeen on MM Alam Road.
When you buy through us, you get:
The RCI-3.0UNZ1NH / RAS-3.0UNZGNH1 delivers 23,300 BTU/h of cooling and 25,640 BTU/h of heating.
Yes. The indoor unit sits inside a false ceiling, with only the grille panel visible. If your space has no false ceiling, a floor-ceiling or floor-standing unit may suit you better.
It’s a Hitachi Non Inverter AC. The fixed-speed compressor runs at full power and switches on and off to hold the set temperature.
Yes. This model offers heat and cool operation, with 25,640 BTU/h of heating capacity and a heating COP of 3.41 W/W.
It features high ambient technology, which is designed to keep the system performing in high outdoor temperatures.
It uses R410A refrigerant.
It runs on 220–240V, 1 phase, 50Hz, which matches standard single-phase supply.
Yes. The auto restart function brings the unit back on with its previous settings once power returns.
Remove the washable filter, rinse it, let it dry fully, and refit it. Regular cleaning helps maintain airflow.
Call or WhatsApp Workman Services on +92 306 4410583, or email info@workmanservices.com.pk. Our team serves Lahore, Rawalpindi, Faisalabad, and other cities.
Reliable 2-ton cooling, stronger winter heating, and high ambient performance make this Hitachi cassette a smart fit for Pakistani summers and winters. Surge protection, a fireproof enclosure, and auto restart add everyday peace of mind. For offices, shops, clinics, showrooms, and large rooms with a false ceiling, it’s a dependable and discreet choice.
Call or WhatsApp Workman Services on +92 306 4410583 to request a quote, book a site survey, and arrange professional installation backed by nearly two decades of HVAC experience.