₨ 1,400,000 Original price was: ₨ 1,400,000.₨ 1,190,000Current price is: ₨ 1,190,000.
Large commercial spaces need more cooling and heating than standard split units can deliver. Warehouses, factories, showrooms, auditoriums, banquet halls and big retail floors have high ceilings, heavy foot traffic and long operating hours. These spaces need a high-capacity system built for continuous use.
The ACSON A5FS100FR-A / A5MC100BR-A is an 8 Ton non-inverter floor-standing commercial air conditioner with heat and cool functions. It uses a dual circuit design, a 10 HP compressor, R410A refrigerant and a 3-phase power supply. It provides year-round climate control in summer and winter.
This guide covers the unit’s features, technical specifications, ideal applications, sizing tips and maintenance needs. It also explains how Workman Services, an HVAC&R solutions provider in Pakistan since 2006, supports commercial buyers with supply, installation, testing, commissioning and maintenance.
The ACSON A5FS100FR-A (indoor) and A5MC100BR-A (outdoor) form a heavy-duty floor-standing cabinet air conditioner for large commercial and industrial spaces. Here are the essential facts:
In Pakistan, this model is commonly listed as an 8 Ton heat and cool floor-standing system under A5FS100FR-A / A5MC100BR-A or similar “-M” variants.
This unit combines high capacity with practical controls for demanding commercial environments. Its main features include:
Summer temperatures in Lahore, Faisalabad and Rawalpindi often go above 40°C. Winters can turn cold, especially in northern Punjab. This ACSON system handles both seasons with one installation.
You don’t need separate heaters for your showroom, hall or factory floor. The auto defrosting function keeps heating performance steady by preventing ice from forming on the outdoor coil in cold weather.
The dual circuit configuration splits the refrigeration system into two independent circuits. This design improves reliability and operating flexibility. If one circuit needs attention, the system is better able to keep some level of comfort, which matters in spaces that run all day.
The 10 HP compressor gives the unit the power to manage large heat loads from people, lighting, machinery and frequent door openings.
R410A is a widely used HFC refrigerant that does not deplete the ozone layer. It offers efficient heat transfer and is familiar to most qualified HVAC technicians in Pakistan.
The unit runs on a 3-phase power supply, which most commercial buildings, factories and warehouses already have. A proper 3-phase connection supports stable operation of high-capacity compressors.
The touch screen control panel makes daily operation simple for facility staff. You can adjust temperature, switch modes and set schedules quickly.
Built-in functions add convenience:
Large halls and warehouses often have hot spots far from the indoor unit. This system pushes conditioned air over long distances, so people at the far end of the room stay comfortable too. The washable inlet air filter keeps airflow strong and is easy to clean on site.
The table below lists the full technical details for this model.
|
Specification |
Details |
|---|---|
|
Brand |
ACSON |
|
Model (Indoor / Outdoor) |
A5FS100FR-A / A5MC100BR-A |
|
Type |
Floor Standing Cabinet |
|
Capacity |
8 Ton (approx. 96,000 BTU/h) |
|
Compressor |
10 HP |
|
Operation Type |
Non-Inverter, Heat & Cool (Dual Circuit) |
|
Refrigerant |
R410A |
|
Power Supply |
3-Phase (typically 380–415V / 50Hz) |
|
Control |
Touch Screen Control |
|
Key Functions |
Auto Restart, Auto Defrosting, Timer, Independent Dehumidification |
|
Airflow |
Strong wind and long-distance air supply |
|
Filter |
Washable Inlet Air Filter |
|
Cooling Type |
Heat & Cool |
|
Air Conditioner Type |
Floor Standing |
|
Cooling Capacity (Listed) |
8.0 Ton |
Specifications may vary slightly between model variants. Workman Services confirms exact details for your order before supply.
Commercial buyers often want high capacity, simple operation and a reasonable upfront cost. An ACSON Non Inverter AC meets all three needs. It delivers full cooling power when you switch it on, which suits busy spaces that heat up fast.
A non inverter AC runs its compressor at a fixed full speed. When the room reaches the set temperature, the compressor switches off. When the temperature rises again, it switches back on.
This simple design offers practical benefits for commercial projects:
For warehouses, factories and halls, choosing an ACSON Non Inverter AC gives you dependable comfort without complex electronics.
An aircon stand unit sits directly on the floor in a tall cabinet. It doesn’t need a false ceiling or strong wall support, which makes installation easier in warehouses, factories and halls with open or very high ceilings.
Floor-standing cabinets offer several advantages in large commercial spaces:
Choosing an aircon with stand design also helps when you’re upgrading an existing building, since you avoid major interior changes.
The table below compares common commercial unit types.
|
Factor |
Floor Standing Cabinet |
Wall-Mounted Split |
Ceiling Cassette |
|---|---|---|---|
|
Typical capacity range |
High (up to 8 Ton and above) |
Low to medium |
Medium |
|
Best for |
Halls, warehouses, factories |
Small rooms and offices |
Offices with false ceilings |
|
Installation complexity |
Low |
Low |
Medium to high |
|
Air throw distance |
Long |
Short |
Medium |
|
Ceiling requirement |
None |
None |
False ceiling needed |
|
Service access |
Easy, floor level |
Moderate |
Requires ceiling access |
This 8 ton floor stand air conditioner is built for spaces where smaller units can’t keep up. The table below shows where it performs best.
|
Application |
Why It Fits |
|---|---|
|
Large halls and banquet halls |
Long-distance airflow covers wide open areas |
|
Warehouses |
High capacity handles large volumes and high ceilings |
|
Factories and manufacturing units |
Manages heat from machinery and workers |
|
Showrooms |
Keeps customers and displays comfortable all day |
|
Auditoriums |
Maintains comfort during crowded events |
|
Big retail areas and supermarkets |
Handles frequent door openings and foot traffic |
|
Wedding marquees and event spaces |
Quick cooling and heating for large gatherings |
|
Industrial workshops |
Built for continuous heavy-duty use |
Capacity alone doesn’t guarantee comfort. Correct sizing depends on several factors:
A professional heat load calculation tells you whether one 8 Ton unit is enough or whether your space needs multiple units, ducting or a VRF or chiller system. Workman Services provides this assessment before recommending equipment.
Workman Services has delivered HVAC&R and fire fighting solutions since 2006. Our team includes experienced designers, qualified sales engineers and certified technicians. We’ve completed commercial HVAC projects at Nishat Galleria Mall, Dolmen Mall, Giga Mall and for many retail and industrial clients.
We provide end-to-end support for your ACSON floor-standing unit:
We serve clients through branches in Lahore, Rawalpindi and Faisalabad, plus our UAE office in Abu Dhabi.
Heavy-duty units need regular care to perform well for years. Follow these steps:
Dust in factories and warehouses can clog coils quickly. Regular maintenance protects your investment and lowers repair costs.
The ACSON A5FS100FR-A / A5MC100BR-A has an 8 Ton capacity, which equals approximately 96,000 BTU/h. It is powered by a 10 HP compressor.
As a general guide, an 8 Ton unit can cover roughly 1,500 to 2,000 square feet in a typical commercial space. Actual coverage depends on ceiling height, insulation, sunlight, occupancy and equipment heat. A heat load calculation gives the most accurate answer.
Yes. Its fixed-speed compressor, dual circuit design and strong airflow make it well suited to factories, warehouses and other spaces with heavy, continuous heat loads.
An inverter unit adjusts compressor speed to match demand, which can save energy in steady-use spaces. A non-inverter unit runs at full speed and cycles on and off. It costs less upfront and is simpler to service.
It’s a floor-standing cabinet air conditioner that sits on the floor instead of mounting on a wall or ceiling. Buyers looking for an aircon with stand design usually need high capacity and easy installation for large spaces.
Yes. The unit requires a 3-phase supply, typically 380–415V at 50Hz. Most commercial and industrial buildings already have this connection.
Dual circuit means the system has two independent refrigeration circuits. This improves reliability and operating flexibility during continuous commercial use.
Yes. We provide supply, installation, testing, commissioning and maintenance through our branches in Lahore, Rawalpindi and Faisalabad.
Call or WhatsApp Workman Services at +92 306 4410583, or email info@workmanservices.com.pk. Share your space size, location and requirements, and our team will recommend the right system.
The ACSON A5FS100FR-A / A5MC100BR-A gives large commercial and industrial spaces powerful cooling, reliable heating and long-distance airflow in one floor-standing system. Its dual circuit design, 10 HP compressor and smart controls make it a strong choice for halls, warehouses, factories, showrooms and big retail areas.
Workman Services handles every step, from heat load calculation and genuine equipment supply to professional installation, commissioning and maintenance. Contact our team today at +92 306 4410583 for expert advice and a quote for your project.



