workmanservices
workmanservices

ACSON 8 Ton Non Inverter Floor Standing Air conditioner Heat and Cool (Dual Circuit)

Sale!

ACSON 8 Ton Non Inverter Floor Standing Air conditioner Heat and Cool (Dual Circuit)

  • 8 Ton High-Capacity Commercial AC
  • A5FS100FR-A / A5MC100BR-A
  • Call/WhatsApp 0306-4410583
  • Approx. 96,000 BTU/h Class
  • Heat & Cool Operation
  • Non-Inverter Technology
  • 10 HP Compressor Class
  • Strong & Long-Distance Air Supply
  • R410A Refrigerant
  • Washable Inlet Air Filter
  • Auto Restart Function
  • Auto Defrosting
  • Timer Function
  • Independent Dehumidification

Price

Original price was: ₨ 1,400,000.Current price is: ₨ 1,190,000.

ACSON 8 Ton AC Floor Standing Heat and Cool (Dual Circuit): Complete Buyer’s Guide

Large commercial spaces need more cooling and heating than standard split units can deliver. Warehouses, factories, showrooms, auditoriums, banquet halls and big retail floors have high ceilings, heavy foot traffic and long operating hours. These spaces need a high-capacity system built for continuous use.

The ACSON A5FS100FR-A / A5MC100BR-A is an 8 Ton non-inverter floor-standing commercial air conditioner with heat and cool functions. It uses a dual circuit design, a 10 HP compressor, R410A refrigerant and a 3-phase power supply. It provides year-round climate control in summer and winter.

This guide covers the unit’s features, technical specifications, ideal applications, sizing tips and maintenance needs. It also explains how Workman Services, an HVAC&R solutions provider in Pakistan since 2006, supports commercial buyers with supply, installation, testing, commissioning and maintenance.

Quick Overview: ACSON A5FS100FR-A / A5MC100BR-A

The ACSON A5FS100FR-A (indoor) and A5MC100BR-A (outdoor) form a heavy-duty floor-standing cabinet air conditioner for large commercial and industrial spaces. Here are the essential facts:

  • Brand: ACSON
  • Indoor / outdoor model: A5FS100FR-A / A5MC100BR-A
  • Capacity: 8 Ton (approximately 96,000 BTU/h)
  • Compressor: 10 HP
  • Operation: Non-inverter, heat and cool, dual circuit
  • Refrigerant: R410A
  • Power supply: 3-phase (typically 380–415V / 50Hz)
  • Control: Touch screen panel
  • Best for: Halls, warehouses, factories, showrooms, auditoriums and large retail areas

In Pakistan, this model is commonly listed as an 8 Ton heat and cool floor-standing system under A5FS100FR-A / A5MC100BR-A or similar “-M” variants.

Key Features of the ACSON 8 Ton AC

This unit combines high capacity with practical controls for demanding commercial environments. Its main features include:

  • Heat and cool functionality: Strong cooling in summer and effective heating in winter
  • 8 Ton high capacity: Approximately 96,000 BTU/h for large open spaces
  • Dual circuit design: Better reliability for continuous heavy-duty operation
  • 10 HP compressor: Powerful, robust performance under heavy loads
  • Fixed-speed operation: Simple and dependable non-inverter technology
  • R410A refrigerant: A more environmentally friendly refrigerant choice
  • 3-phase power supply: Built for commercial electrical systems
  • Touch screen control: A modern, easy-to-use interface
  • Strong wind and long-distance air supply: Even airflow across wide areas
  • Washable inlet air filter: Easy cleaning and lower upkeep costs
  • Auto restart: Resumes previous settings after a power failure
  • Auto defrosting: Prevents ice buildup during heating mode
  • Timer function: Schedule operation around business hours
  • Independent dehumidification: Controls indoor humidity without overcooling

Heat and Cool Operation for Year-Round Comfort

Summer temperatures in Lahore, Faisalabad and Rawalpindi often go above 40°C. Winters can turn cold, especially in northern Punjab. This ACSON system handles both seasons with one installation.

You don’t need separate heaters for your showroom, hall or factory floor. The auto defrosting function keeps heating performance steady by preventing ice from forming on the outdoor coil in cold weather.

Dual Circuit Design and 10 HP Compressor

The dual circuit configuration splits the refrigeration system into two independent circuits. This design improves reliability and operating flexibility. If one circuit needs attention, the system is better able to keep some level of comfort, which matters in spaces that run all day.

The 10 HP compressor gives the unit the power to manage large heat loads from people, lighting, machinery and frequent door openings.

R410A Refrigerant and 3-Phase Power

R410A is a widely used HFC refrigerant that does not deplete the ozone layer. It offers efficient heat transfer and is familiar to most qualified HVAC technicians in Pakistan.

The unit runs on a 3-phase power supply, which most commercial buildings, factories and warehouses already have. A proper 3-phase connection supports stable operation of high-capacity compressors.

Touch Screen Control and Smart Functions

The touch screen control panel makes daily operation simple for facility staff. You can adjust temperature, switch modes and set schedules quickly.

Built-in functions add convenience:

  • Timer: Start or stop the unit automatically to match working hours.
  • Auto restart: Saves time after load shedding or power cuts.
  • Independent dehumidification: Reduces moisture during humid monsoon months.

Strong Wind and Long-Distance Air Supply

Large halls and warehouses often have hot spots far from the indoor unit. This system pushes conditioned air over long distances, so people at the far end of the room stay comfortable too. The washable inlet air filter keeps airflow strong and is easy to clean on site.

ACSON 8 Ton AC Technical Specifications

The table below lists the full technical details for this model.

Specification

Details

Brand

ACSON

Model (Indoor / Outdoor)

A5FS100FR-A / A5MC100BR-A

Type

Floor Standing Cabinet

Capacity

8 Ton (approx. 96,000 BTU/h)

Compressor

10 HP

Operation Type

Non-Inverter, Heat & Cool (Dual Circuit)

Refrigerant

R410A

Power Supply

3-Phase (typically 380–415V / 50Hz)

Control

Touch Screen Control

Key Functions

Auto Restart, Auto Defrosting, Timer, Independent Dehumidification

Airflow

Strong wind and long-distance air supply

Filter

Washable Inlet Air Filter

Cooling Type

Heat & Cool

Air Conditioner Type

Floor Standing

Cooling Capacity (Listed)

8.0 Ton

Specifications may vary slightly between model variants. Workman Services confirms exact details for your order before supply.

Why Choose an ACSON Non Inverter AC for Commercial Use

Commercial buyers often want high capacity, simple operation and a reasonable upfront cost. An ACSON Non Inverter AC meets all three needs. It delivers full cooling power when you switch it on, which suits busy spaces that heat up fast.

How a Non Inverter AC Works

A non inverter AC runs its compressor at a fixed full speed. When the room reaches the set temperature, the compressor switches off. When the temperature rises again, it switches back on.

This simple design offers practical benefits for commercial projects:

  • Lower upfront cost than many inverter systems of similar capacity
  • Proven, straightforward technology
  • Easier troubleshooting and faster repairs
  • Strong performance in spaces with heavy, constant heat loads

For warehouses, factories and halls, choosing an ACSON Non Inverter AC gives you dependable comfort without complex electronics.

Floor Standing Design: The Aircon Stand Advantage

An aircon stand unit sits directly on the floor in a tall cabinet. It doesn’t need a false ceiling or strong wall support, which makes installation easier in warehouses, factories and halls with open or very high ceilings.

Benefits of an Aircon with Stand Design

Floor-standing cabinets offer several advantages in large commercial spaces:

  • High airflow capacity: The tall cabinet moves large volumes of air.
  • Simple installation: No ceiling work or heavy wall brackets needed.
  • Easy access for servicing: Technicians can reach filters and parts at floor level.
  • Flexible placement: The unit can stand in a corner or along a wall facing the main area.

Choosing an aircon with stand design also helps when you’re upgrading an existing building, since you avoid major interior changes.

The table below compares common commercial unit types.

Factor

Floor Standing Cabinet

Wall-Mounted Split

Ceiling Cassette

Typical capacity range

High (up to 8 Ton and above)

Low to medium

Medium

Best for

Halls, warehouses, factories

Small rooms and offices

Offices with false ceilings

Installation complexity

Low

Low

Medium to high

Air throw distance

Long

Short

Medium

Ceiling requirement

None

None

False ceiling needed

Service access

Easy, floor level

Moderate

Requires ceiling access

Ideal Applications for a Floor Stand Air Conditioner

This 8 ton floor stand air conditioner is built for spaces where smaller units can’t keep up. The table below shows where it performs best.

Application

Why It Fits

Large halls and banquet halls

Long-distance airflow covers wide open areas

Warehouses

High capacity handles large volumes and high ceilings

Factories and manufacturing units

Manages heat from machinery and workers

Showrooms

Keeps customers and displays comfortable all day

Auditoriums

Maintains comfort during crowded events

Big retail areas and supermarkets

Handles frequent door openings and foot traffic

Wedding marquees and event spaces

Quick cooling and heating for large gatherings

Industrial workshops

Built for continuous heavy-duty use

How to Choose the Right Capacity for Your Space

Capacity alone doesn’t guarantee comfort. Correct sizing depends on several factors:

  • Floor area and ceiling height
  • Building insulation and roof type
  • Sun exposure and window area
  • Number of people in the space
  • Heat from machinery, lighting and cooking equipment
  • How often doors open to the outside

A professional heat load calculation tells you whether one 8 Ton unit is enough or whether your space needs multiple units, ducting or a VRF or chiller system. Workman Services provides this assessment before recommending equipment.

How Workman Services Supports Your HVAC Project

Workman Services has delivered HVAC&R and fire fighting solutions since 2006. Our team includes experienced designers, qualified sales engineers and certified technicians. We’ve completed commercial HVAC projects at Nishat Galleria Mall, Dolmen Mall, Giga Mall and for many retail and industrial clients.

We provide end-to-end support for your ACSON floor-standing unit:

  1. Consultation: We review your space, usage hours and comfort needs.
  2. Heat load calculation: We confirm the right capacity and number of units.
  3. Supply: We provide genuine ACSON equipment, along with options from Midea, Gree, Hitachi, Super General and Eco Star.
  4. Installation: Our technicians handle indoor and outdoor units, copper piping, drainage and 3-phase electrical connections.
  5. Testing and commissioning: We check pressures, airflow and performance before handover.
  6. Maintenance: We offer ongoing service to keep your system running efficiently.

We serve clients through branches in Lahore, Rawalpindi and Faisalabad, plus our UAE office in Abu Dhabi.

Maintenance Tips for Long-Term Performance

Heavy-duty units need regular care to perform well for years. Follow these steps:

  • Clean the washable inlet filter every two to four weeks in dusty environments.
  • Keep the outdoor unit clear of dust, debris and blocked airflow.
  • Schedule professional servicing before summer and before winter.
  • Check drain lines to prevent leaks and water damage.
  • Have technicians inspect refrigerant pressure and 3-phase electrical connections.
  • Keep the front of the cabinet clear of stock, racks or displays.

Dust in factories and warehouses can clog coils quickly. Regular maintenance protects your investment and lowers repair costs.

Frequently Asked Questions

What Is the Cooling Capacity of the ACSON A5FS100FR-A?

The ACSON A5FS100FR-A / A5MC100BR-A has an 8 Ton capacity, which equals approximately 96,000 BTU/h. It is powered by a 10 HP compressor.

How Much Area Can an 8 Ton Floor Stand Air Conditioner Cover?

As a general guide, an 8 Ton unit can cover roughly 1,500 to 2,000 square feet in a typical commercial space. Actual coverage depends on ceiling height, insulation, sunlight, occupancy and equipment heat. A heat load calculation gives the most accurate answer.

Is the ACSON Non Inverter AC Good for Factories and Warehouses?

Yes. Its fixed-speed compressor, dual circuit design and strong airflow make it well suited to factories, warehouses and other spaces with heavy, continuous heat loads.

What Is the Difference Between an Inverter and a Non Inverter AC?

An inverter unit adjusts compressor speed to match demand, which can save energy in steady-use spaces. A non-inverter unit runs at full speed and cycles on and off. It costs less upfront and is simpler to service.

What Is an Aircon Stand Unit?

It’s a floor-standing cabinet air conditioner that sits on the floor instead of mounting on a wall or ceiling. Buyers looking for an aircon with stand design usually need high capacity and easy installation for large spaces.

Does This Unit Need a 3-Phase Power Supply?

Yes. The unit requires a 3-phase supply, typically 380–415V at 50Hz. Most commercial and industrial buildings already have this connection.

What Does Dual Circuit Mean?

Dual circuit means the system has two independent refrigeration circuits. This improves reliability and operating flexibility during continuous commercial use.

Does Workman Services Install This Unit in Lahore, Rawalpindi and Faisalabad?

Yes. We provide supply, installation, testing, commissioning and maintenance through our branches in Lahore, Rawalpindi and Faisalabad.

How Can I Get a Quote?

Call or WhatsApp Workman Services at +92 306 4410583, or email info@workmanservices.com.pk. Share your space size, location and requirements, and our team will recommend the right system.

Get the ACSON 8 Ton AC from Workman Services

The ACSON A5FS100FR-A / A5MC100BR-A gives large commercial and industrial spaces powerful cooling, reliable heating and long-distance airflow in one floor-standing system. Its dual circuit design, 10 HP compressor and smart controls make it a strong choice for halls, warehouses, factories, showrooms and big retail areas.

Workman Services handles every step, from heat load calculation and genuine equipment supply to professional installation, commissioning and maintenance. Contact our team today at +92 306 4410583 for expert advice and a quote for your project.

Related Products